TECHNICAL DATA Frontal panel protection: IP65.Casing: plastic body in resin
type PC+ABS UL94 V-0, inspection window in polycarbonate, buttons in
thermoplastic resin. Dimensions: frontal panel 74x32 mm, depth 59 mm
(without wirings). Installation: on panel, with drilling tem- plate 71x29
mm (+0.2/–0.1 mm). Use temperature: –5…55 °C. Storage temperature.: –30…85
°C. Use environment humidity: 10…90 % RH (not condensing). Storage
environment humidity: 10…90% RH (not condensing). Serial: TTL for
connection to Copy Card and (LX MODELS) TelevisSystem. Analog input: one
PTC or NTC input (programmable by parameter). Digital input (ONLY LX
MODELS) 1 voltage-free digital input that can be set by parameter. Digital
outputs: 1 SPDT output on 8(3)A 1/2 hp, 1 SPST output on 8(3)A 1/2
hp configurables. (for relay capabilities see label on the
instrument) Buzzer output: only on models with Buzzer. Warning: check
the power supply specified on the instrument label; for relay and power
supply capacities, contact the Sales Office).
Pt100-TcJ/TcK MODELS Display range: • model Pt100: -150…650°C,
with decimal point based on ndt parameter • model TcJ -40…750°C* •
model TcK -40…1350°C* *without decimal point 3 and a half digit display +
sign. NOTE: display is therefore to the near- est tenth of a degree °C in
model Pt100 and to the nearest degree °C in models TcJ/TcK Analogue
input: one Pt100 or TcJ or TcK input, depending on model; Measurement
range: from -150 to 1350. Accuracy:
|
• model Pt100: 0,5% throughout range +
1 digit; 0,2% from -150 to 300°C. • model TcJ 0,4% throughout range +
1 digit; • model TcK 0,5% throughout range + 1 digit; 0,3% from -40 to
800°C. Resolution: • model Pt100: 0,1°C (0,1°F) up to 199,9 °C, 1°C
(1°F) beyond • model TcJ/TcK 1°C (1°F). Resolution: • model Pt100:
0,1°C (0,1°F) up to 199,9 °C, 1°C (1°F) beyond • model TcJ/TcK 1°C
(1°F). Consumption: • model 230V: 3 VA max.; • model 12/24V: 1,5 VA
max. Power supply: 12/24 V a / c ±10% or 230V a ±10% 50/60 Hz. NTC-PTC
MODELS Display range: • NTC probe: –50…110°C (–58…230°F); • PTC probe:
–55…140°C (–58…302°F) 3 and a half digit display + sign. Analogue input:
one PTC or NTC input (selectable with parameter). Measurement range: –55
to 140 °C. Accuracy: better than 0.5% of bottom of the scale + 1
digit. Resolution: 0,1°C (0,1°F to +199,9°F;
1°F beyond). Consumption: • 230V model: 3 VA max.; • 12/24V model:
1,5 VA max. Power supply: 12/24 V a / c ±10% or 230V a ±10% 50/60 Hz.
|