| Show All - Àüüº¸±â | ÀÎÅͳÝ+ÀΰøÁö´É/IoT&AI | ¸ÞÀÌÄ¿º°±¸ºÐ(Brands) | °øÀå (FA)½Ã½ºÅÛ | ¿î¼ÛÀåºñ-Transport | ºôµù/¾ÆÆÄÆ®-Bldg/Apt | ·¹Á®/½ºÆ÷Ã÷-Leports | Áö¿ª³­¹æ-District Heating | º¸ÀÏ·¯/³Ãµ¿±â-Boiler/Freez | ¼­¸Ó½ºÅ¸Æ®-Thermostats | ¼Ò¹æ/¾ÈÀü-Fire/Securty | ÆßÇÁ-Pumps | ¹ëºê-Valves | ¼¾¼­/½ºÀ§Ä¡-Sensor/Switch | ¼Ö·¹³ëÀ̵å(Solenoids) | ¸ðÅÍ¿Í °¨¼Ó±â(Motors) | °èÃø/°è·®/±â·Ï°è(Meter) | Àü±â¿ä¼ÒºÎÇ°(Elec.compo) | ½ºÀ§Äª¼¾¼­-Switches | ÀιöÅÍ-Inverter drives | ¿µ»ó°¨½Ã-CCTVs | ´ÜÁ¾Ç°/Èñ±ÍÇ°(Rare) | µµ¿ÍÁÖ¼¼¿ä(Help!!) | ±â¼ú Áö½Ä ¼¾ÅÍ(Knowlege) | PC& Periferals-PCÁÖº¯±â±â | Controls- News | ¼³ºñÀÚÀç-Pipe&Fittings | ±â°èºÎÇ°-MachineParts | °ø±¸·ù-Tools | Áß°íÇ°-Used Parts | ¾ÆÀ̵ð¾îÁ¦Ç°¸ðÀ½-Idea | ¿¡³ÊÁö°ü·Ã±â±â-Energy | ÀüüijƼ°í¸®-ShowAll | ½ºÆä¼È ¾ÆÀÌÅ×-Special Items
¸ÞÀÎ :: °øÀå (FA)½Ã½ºÅÛ :: PLCs(ÇÇ¿¤¾¾)) :: AB :: PLC :: CPU ¸ðµâ :: CPU ¸ðµâ
CPU ¸ðµâ
SLC Processors SLC Processors

  • Use the following tables to select the SLC processor that fits your application.
  • Data table maximum words is user configured.
  • Maximum timers/counters is restricted only by memory.


Cat. No. User Memory, Max. Number of I/O Local Analog I/O, Max. Program Scan Time/Kword I/O Scan Time
SLC 5/01 Processor
1747-L511 1K instructions 960 absolute maximum (local)T  480 8 ms (typ) 2.6 ms (typ)
1747-L514 4K instructions
SLC 5/02 Processor
1747-L524 4K instructions 4096 in + 4096 out
absolute maximumT 
480 4.8 ms (typ) 1.6 ms (typ)
SLC 5/03 Processor¬ 
1747-L531 8K words total
(4K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
absolute maximumT 
180 1 ms (typ) 0.225 ms (typ)
1747-L532 16K words total
(12K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
absolute maximumT ¢Ô 
480
SLC 5/04 Processor
1747-L541 16K words total
(12K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
absolute maximumT ¢Ô 
480 0.9 ms (typ) 0.225 ms (typ)
1747-L542 32K words total
(28K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
absolute maximumT ¢Ô 
1747-L543 64K words total
(60K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
maximumT 
SLC 5/05 Processor ¡× 
1747-L551 16K words total
(12K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
absolute maximumT ¢Ô 
480 0.9 ms (typ) 0.225 ms (typ)
1747-L552 32K words total
(28K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
absolute maximumT ¢Ô 
1747-L553 64K words total
(60K words for data or prog.)
(4K words for data only)
4096 in + 4096 out
maximum¢Ô 
  
¬ Modbus slave protocol is embedded in the RTU-5/03 processors available from an Encompass partner. The Modbus slave protocol is supported on the RS-232 port (channel0). For information on the Encompass program visit: www.automation.rockwell.com/encompass/.
T The absolute maximum number of I/O for these processors only reflects the I/O addressing capability. It does not take into account the amount of memory that may be required for a ladder-logic program to monitor and control the I/O. The practical ratio of memory per I/O is totally dependant upon your specific application.
¢Ô You cannot configure this number of I/O for these processors with local I/O only. To configure this number of I/O for these processors, you must add a 1747-SN Remote I/O Scanner module to configure I/O on a Universal Remote I/O link, add a 1747-SDN DeviceNet Scanner module to configure I/O on a DeviceNet network and/or add a 1747-SCNR ControlNet Scanner module to configure I/O on a ControlNet network.
¡× The 5/05 Series C processors can communicate to 100 Mbps and support increased Ethernet connections: 1747-L551=32 connections; 1747-L552=48 connections; 1747-L553=64 connections.


SLC Processors (continued)

Cat. No. No. of Local I/O Chassis, Max. No. of I/O Module Slots in the Local I/O Chassis, Max. Communication
Ports
Backup
Memory
Battery-backed
RAM
Backplane
Current Load
SLC 5/01 Processor
1747-L511
1747-L514
3 30 DH-485T  EEPROM Option 350 mA @ 5V dc
105 mA @ 24V dc
SLC 5/02 Processor
1747-L524 3¬  30 DH-485 EEPROM Standard 350 mA @ 5V dc
105 mA @ 24V dc
SLC 5/03 Processor
1747-L531
1747-L532
3¬  30 DH-485
RS-232¢Ô 
Flash Standard 500 mA @ 5V dc
175 mA @ 24V dc
SLC 5/04 Processor
1747-L541
1747-L542
1747-L543
3¬  30 DH+
RS-232¡× 
Flash Standard 1.0A @ 5V dc
0 mA @ 24V dc¡× 
SLC 5/05 Processor
1747-L551
1747-L552
1747-L553
3¬  30 Ethernet
RS-232¡× 
Flash Standard 1.0A @ 5V dc
0 mA @ 24V dc
  
¬ With this processor, you can also install a 1747-SN Remote I/O Scanner module to configure I/O on a Universal Remote I/O link and/or add a 1747-SDN DeviceNet Scanner module to configure I/O on a DeviceNet network. You can configure 32 I/O chassis per Universal Remote I/O scanner using complementary I/O. If you don¡¯t use complementary I/O, you can configure 16 I/O chassis per Universal Remote I/O scanner. With the DeviceNet scanner, you can address a maximum of 63 DeviceNet devices over the DeviceNet network.
T An SLC 5/01 processor can only receive messages and send reply messages to command messages sent from other nodes on the DH-485 network; it cannot initiate communication.
¢Ô The SLC 5/03 has an RS-232 port, which can also be configured for a DH-485 network, enabling the SLC-5/03 to connect to two DH-485 networks simultaneously.
¡× The SLC 5/04 and SLC 5/05 have an RS-232 port, which can also be configured for a DH-485 network.
¡× SLC 5/04 processors manufactured prior to April 2002 draw 200 mA @ 24V dc. Check the processor label to verify current draw.

ÇöÀç ºÐ·ù¿¡ µî·ÏµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.

°øµ¿±¸¸Å | ȸ»ç¼Ò°³ | °³ÀÎÁ¤º¸Ãë±Þ¹æħ | ÀÌ¿ë¾à°ü | °í°´ ¼­ºñ½º ¼¾ÅÍ | ·Î±×ºÐ¼® | ã¾Æ ¿À½Ã´Â ±æ | °Å·¡ÀºÇàÁ¤º¸ | »ç¾÷ÀÚ°ü·Ã¼­·ù | °ü¸®

»óÇ° À̹ÌÁö ÀúÀÛ±ÇÀº A.T.I »ç¿¡ ÀÖ½À´Ï´Ù. ¹«´ÜÀ¸·Î °Ô½ÃÇϰųª ÆǸÅ, ´ë¿© ¶Ç´Â »ó¾÷Àû ¸ñÀûÀ¸·Î
ÀÌ¿ë½Ã´Â ¼ÕÇعè»óÀÇ Ã¥ÀÓ°ú ó¹úÀ» ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù

Copyright (c) 2003~2024 Automation Technologies Co., Ltd. All rights reserved.
º»»ç:   »ç¾÷ÀÚµî·Ï¹øÈ£:   107-87-19475    ´ëÇ¥ÀÌ»ç:±è ÇöÈ£    »óÈ£:(ÁÖ)¿ÀÅä¸ÞÀ̼ÇÅ×Å©³î·ÎÁöÁî(ATI)
º»»çÁÖ¼Ò:¼­¿ï½Ã¿µµîÆ÷±¸¿©ÀÇ´ë·Î8 ¿©ÀǵµÆÄÅ©¼¾ÅÍ A-604    |°øÀå:°æ±âµµ±èÆ÷½ÃÇϼº¸éÈÄÆò·Î56 | ¹°·ù¼¾ÅÍ:°æ±âµµ±èÆ÷½Ãµµ¼º¸éÈÄÆò·Î60(ÈÄÆò¸®478-1)
±â¼ú»ó´ãÀº °¡´ÉÇÏ¸é ¸ÞÀÏ ¶Ç´Â Æѽº ÁÖ½Ã¸é °¨»çÇÏ°Ú½À´Ï´Ù. ±ä±Þ±¸¸Å ¹× ¹è¼Û/¹Ý¼Û»ó´ã: 1577-6870. °ßÀûÀÇ·Ú¼­->Æѽº:02-784-1218/02-6937-1643
°ßÀû»ó´ã-->E-mail: kjkim@controlmart.co.kr ¹è¼Û»ó´ã-> E-mail:kjkim@controlmart.co.kr ÀüÀÚ¼¼±Ý°è»ê¼­->idrago@naver.com ±â¼ú»ó´ã-> E-mail: kjkim@ati1980.com
AS½ëÅÍ:°æ±âµµ±èÆ÷½ÃÇϼº¸éÈÄÆò·Î60 (ÈÄÆò¸®478-1)±â¼ú»ó´ã(À¯·á¿¹°í): 010-5263-3650 : Fax:02-784-1218/031-982-9492/E-mail:kjkim@ati1980.com
scrol banner