Cat. No. |
User Memory, Max. |
Number of I/O |
Local Analog I/O, Max. |
Program Scan Time/Kword |
I/O Scan Time |
SLC 5/01 Processor |
1747-L511 |
1K instructions |
960 absolute maximum
(local)T |
480 |
8 ms (typ) |
2.6 ms (typ) |
1747-L514 |
4K instructions |
SLC 5/02 Processor |
1747-L524 |
4K instructions |
4096 in + 4096 out absolute
maximumT |
480 |
4.8 ms (typ) |
1.6 ms (typ) |
SLC 5/03 Processor¬ |
1747-L531 |
8K words total (4K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out absolute
maximumT |
180 |
1 ms (typ) |
0.225 ms (typ) |
1747-L532 |
16K words total (12K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out absolute
maximumT ¢Ô |
480 |
SLC 5/04 Processor |
1747-L541 |
16K words total (12K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out absolute
maximumT ¢Ô |
480 |
0.9 ms (typ) |
0.225 ms (typ) |
1747-L542 |
32K words total (28K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out absolute
maximumT ¢Ô |
1747-L543 |
64K words total (60K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out maximumT |
SLC 5/05 Processor ¡×
|
1747-L551 |
16K words total (12K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out absolute
maximumT ¢Ô |
480 |
0.9 ms (typ) |
0.225 ms (typ) |
1747-L552 |
32K words total (28K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out absolute
maximumT ¢Ô |
1747-L553 |
64K words total (60K words for data or
prog.) (4K words for data only) |
4096 in + 4096 out maximum¢Ô |
|
¬ Modbus slave protocol is
embedded in the RTU-5/03 processors available from an Encompass partner. The
Modbus slave protocol is supported on the RS-232 port (channel0). For
information on the Encompass program visit: www.automation.rockwell.com/encompass/. T The absolute maximum number of I/O for these processors
only reflects the I/O addressing capability. It does not take into account the
amount of memory that may be required for a ladder-logic program to monitor and
control the I/O. The practical ratio of memory per I/O is totally dependant upon
your specific application. ¢Ô You cannot configure this number of I/O for
these processors with local I/O only. To configure this number of I/O for these
processors, you must add a 1747-SN Remote I/O Scanner module to configure I/O on
a Universal Remote I/O link, add a 1747-SDN DeviceNet Scanner module to
configure I/O on a DeviceNet network and/or add a 1747-SCNR ControlNet Scanner
module to configure I/O on a ControlNet network. ¡× The 5/05 Series C
processors can communicate to 100 Mbps and support increased Ethernet
connections: 1747-L551=32 connections; 1747-L552=48 connections; 1747-L553=64
connections. |