| Show All - Àüüº¸±â | ÀÎÅͳÝ+ÀΰøÁö´É/IoT&AI | ¸ÞÀÌÄ¿º°±¸ºÐ(Brands) | °øÀå (FA)½Ã½ºÅÛ | ¿î¼ÛÀåºñ-Transport | ºôµù/¾ÆÆÄÆ®-Bldg/Apt | ·¹Á®/½ºÆ÷Ã÷-Leports | Áö¿ª³­¹æ-District Heating | º¸ÀÏ·¯/³Ãµ¿±â-Boiler/Freez | ¼­¸Ó½ºÅ¸Æ®-Thermostats | ¼Ò¹æ/¾ÈÀü-Fire/Securty | ÆßÇÁ-Pumps | ¹ëºê-Valves | ¼¾¼­/½ºÀ§Ä¡-Sensor/Switch | ¼Ö·¹³ëÀ̵å(Solenoids) | ¸ðÅÍ¿Í °¨¼Ó±â(Motors) | °èÃø/°è·®/±â·Ï°è(Meter) | Àü±â¿ä¼ÒºÎÇ°(Elec.compo) | ½ºÀ§Äª¼¾¼­-Switches | ÀιöÅÍ-Inverter drives | ¿µ»ó°¨½Ã-CCTVs | ´ÜÁ¾Ç°/Èñ±ÍÇ°(Rare) | µµ¿ÍÁÖ¼¼¿ä(Help!!) | ±â¼ú Áö½Ä ¼¾ÅÍ(Knowlege) | PC& Periferals-PCÁÖº¯±â±â | Controls- News | ¼³ºñÀÚÀç-Pipe&Fittings | ±â°èºÎÇ°-MachineParts | °ø±¸·ù-Tools | Áß°íÇ°-Used Parts | ¾ÆÀ̵ð¾îÁ¦Ç°¸ðÀ½-Idea | ¿¡³ÊÁö°ü·Ã±â±â-Energy | ÀüüijƼ°í¸®-ShowAll | ½ºÆä¼È ¾ÆÀÌÅ×-Special Items
¸ÞÀÎ :: °øÀå (FA)½Ã½ºÅÛ :: PLCs(ÇÇ¿¤¾¾)) :: AB :: PLC :: I/O ¸ðµâ :: ¾Æ³ª·Î±× I/O ¸ðµâ :: ¼±Åà Å×À̺í
¼±Åà Å×À̺í
Analog I/O Modules ¾Æ³ª·Î±× I/O ¸ðµâ

1746 Analog I/O modules do not require external power.

Cat. No. Number of Inputs Backplane Current Load Bandwidth Step
Response
@ 95%
Update
Period
Resolution (bits), Max.¬ 
1746-NI4 4 inputs (±10V dc, ±20 mA) 25 mA @ 5V
85 mA @ 24V
10 Hz 60 ms 512 ms 16
1746-NI8 8 inputs (±10V dc, ±20 mA) 200 mA @ 5V
100 mA @ 24V
1¡¦75 Hz 0.75¡¦730 ms @ 99%T  6 ms / 8 chan 16
1746-NI16I 16 inputs (±20 mA, 4¡¦20 mA, 0¡¦1 mA, or 0¡¦20 mA) 125 mA @ 5V
75 mA @ 24V
6¡¦250 Hz 9¡¦630 msT  16
1746-NI16V 16 inputs (±10V dc, 1¡¦5V dc, 0¡¦5V dc, or 0¡¦10V dc) 125 mA @ 5V
75 mA @ 24V
6¡¦250 Hz 9¡¦630 msT  16
  
¬ For each module, the data format is BCD or natural binary.
T A function of the input filter selection.


1746 Analog Output Modules

Cat. No. Number of Outputs Backplane Current Load Bandwidth Step
Response
@ 95%
Update
Period
Resolution (bits), Max.¬ 
1746-NO4I 4 outputs (0¡¦20 mA) 55 mA @ 5V
195 mA @ 24V
2.5 ms 512 ms 14
1746-NO4V 4 outputs (±10V dc) 55 mA @ 5V
145 mA @ 24V
2.5 ms 512 ms 14
1746-NO8I 8 outputs (0¡¦20 mA) 120 mA @ 5V
250 mA @ 24V
1.0 ms 540 ms / 8 channel 16
1746-NO8V 8 outputs (±10V dc) 120 mA @ 5V
160 mA @ 24V
1.0 ms 540 ms / 8 channel 16
  
¬ For each module, the data format is BCD or natural binary.
T A function of the input filter selection.


1746 Analog Combination Modules

Cat. No. Number of Inputs/ Outputs Backplane Current Load Bandwidth Step
Response
@ 95%
Update
Period
Resolution (bits), Max.¬ 
1746-NIO4V 2 inputs (±10V dc, ±20 mA)
2 outputs (±10V dc)
55 mA @ 5V
115 mA @ 24V
10 Hz 60 ms in
2.5 ms out
512 ms 16 in
14 out
1746-NIO4I 2 inputs (±10V dc, ±20 mA)
2 outputs (0-20 mA)
55 mA @ 5V
145 mA @ 24V
10 Hz 60 ms in
2.5 ms out
512 ms 16 in
14 out
1746-FIO4I
(current outputs)
2 inputs (differential, 0¡¦10V dc, 0¡¦20 mA)
2 outputs (0¡¦20 mA)
55 mA @ 5V
150 mA @ 24V
7 kHz 100 ms in
2.5 ms out
512 ms 12 in
14 out
1746-FIO4V
(voltage outputs)
2 inputs (differential, 0¡¦10V dc, 0¡¦20 mA)
2 outputs (±10V dc)
55 mA @ 5V
120 mA @ 24V
7 kHz 100 ms in
2.5 ms out
512 ms 12 in
14 out
  
¬ For each module, the data format is BCD or natural binary.
T A function of the input filter selection.


1746 RTD and Thermocouple Modules

Cat. No. Number of Inputs Backplane Current Load Bandwidth Step
Response
@ 95%
Update
Period
Resolution (bits), Max.¬ 
1746-NR4
RTD/Resistance
Analog Input Module
4 inputs
100W, 200W, 500W Platinum
120W Nickel
604W Nickel/Iron
10W Copper
150W, 500W, 1000W, 3000W direct resistance
50 mA @ 5V
50 mA @ 24V
2.62¡¦65.5 Hz 12¡¦300 ms 17 ms to 1.2s 16
1746-NR8
RTD/Resistance
Analog Input Module
8 inputs
100W, 200W, 500W Platinum
120W Nickel
604W Nickel/Iron
10W Copper
150W, 500W, 1000W, 3000W direct resistance
100 mA @ 5V
55 mA @ 24V
7.80¡¦1677 Hz 1.47¡¦120 ms 6 ms to 2s 16
1746-NT4
Thermocouple/mV
Analog Input Module
4 inputs
B, E, J, K, N, R, S, T Thermocouple and
±50 mV or ±100 mV
60 mA @ 5V
40 mA @ 24V
2.62¡¦65.5 Hz 12¡¦300 ms 26 ms to 1.2s 16
1746-NT8
Thermocouple/mV
Analog Input Module
8 inputs
B, E, J, K, N, R, S, T Thermocouple and
±50mV or ±100mV
120 mA @ 5V
70 mA @ 24V
10¡¦250 Hz 400 ms 356 ms to 4.05s 16
1746-INT4
Isolated Thermocouple/mV
Analog Input Module
4 inputs
B, C, D, E, J, K, N, R, S, T Thermocouple and
±50mV or ±100mV
110 mA @ 5V
85 mA @ 24V
8 Hz 400 ms 500 ms 16
  
¬ For each module, the data format is BCD or natural binary.
T A function of the input filter selection.

 

  ¢Æ ¼±Åà Å×À̺í Ä«Å×°í¸®¿¡ ÃÑ 0°³ÀÇ »óÇ°ÀÌ ÁغñµÇ¾îÀÖ½À´Ï´Ù.
ÇöÀç ºÐ·ù¿¡ µî·ÏµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.

°øµ¿±¸¸Å | ȸ»ç¼Ò°³ | °³ÀÎÁ¤º¸Ãë±Þ¹æħ | ÀÌ¿ë¾à°ü | °í°´ ¼­ºñ½º ¼¾ÅÍ | ·Î±×ºÐ¼® | ã¾Æ ¿À½Ã´Â ±æ | °Å·¡ÀºÇàÁ¤º¸ | »ç¾÷ÀÚ°ü·Ã¼­·ù | °ü¸®

»óÇ° À̹ÌÁö ÀúÀÛ±ÇÀº A.T.I »ç¿¡ ÀÖ½À´Ï´Ù. ¹«´ÜÀ¸·Î °Ô½ÃÇϰųª ÆǸÅ, ´ë¿© ¶Ç´Â »ó¾÷Àû ¸ñÀûÀ¸·Î
ÀÌ¿ë½Ã´Â ¼ÕÇعè»óÀÇ Ã¥ÀÓ°ú ó¹úÀ» ¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù

Copyright (c) 2003~2024 Automation Technologies Co., Ltd. All rights reserved.
º»»ç:   »ç¾÷ÀÚµî·Ï¹øÈ£:   107-87-19475    ´ëÇ¥ÀÌ»ç:±è ÇöÈ£    »óÈ£:(ÁÖ)¿ÀÅä¸ÞÀ̼ÇÅ×Å©³î·ÎÁöÁî(ATI)
º»»çÁÖ¼Ò:¼­¿ï½Ã¿µµîÆ÷±¸¿©ÀÇ´ë·Î8 ¿©ÀǵµÆÄÅ©¼¾ÅÍ A-604    |°øÀå:°æ±âµµ±èÆ÷½ÃÇϼº¸éÈÄÆò·Î56 | ¹°·ù¼¾ÅÍ:°æ±âµµ±èÆ÷½Ãµµ¼º¸éÈÄÆò·Î60(ÈÄÆò¸®478-1)
±â¼ú»ó´ãÀº °¡´ÉÇÏ¸é ¸ÞÀÏ ¶Ç´Â Æѽº ÁÖ½Ã¸é °¨»çÇÏ°Ú½À´Ï´Ù. ±ä±Þ±¸¸Å ¹× ¹è¼Û/¹Ý¼Û»ó´ã: 1577-6870. °ßÀûÀÇ·Ú¼­->Æѽº:02-784-1218/02-6937-1643
°ßÀû»ó´ã-->E-mail: kjkim@controlmart.co.kr ¹è¼Û»ó´ã-> E-mail:kjkim@controlmart.co.kr ÀüÀÚ¼¼±Ý°è»ê¼­->idrago@naver.com ±â¼ú»ó´ã-> E-mail: kjkim@ati1980.com
AS½ëÅÍ:°æ±âµµ±èÆ÷½ÃÇϼº¸éÈÄÆò·Î60 (ÈÄÆò¸®478-1)±â¼ú»ó´ã(À¯·á¿¹°í): 010-5263-3650 : Fax:02-784-1218/031-982-9492/E-mail:kjkim@ati1980.com
scrol banner